Product introduction:
Technical specification for laser diameter measuring instrument:
Measuring instrument size
(mm) length 290 width 66 height 170
Length 425 width 68 height 212
Length 504 width 68 height 230
Length 260 width 66 height 270
Length 260 width 66 height 270
Length 360 width 68 height 402
Length 674 width 68 height 654
Measuring instrument weight: 5kg 8kg 10kg 7.5kg 7.5kg 14kg 20kg
Measurement speed: 600 scan / sec 600 times scan / sec 600 times scan / sec 1200 scan / sec 1200 times scan / second 1200 times scan / second 1200 times scan / sec.
Measurement unit: mm, inch.
Measuring instrument power: 24 Vdc 1 Amp.
Temperature range: 5oC ~ 45oC.
Relative humidity: 90% 38oC.
Protection level: IP65, NEMA4.
Diameter meter serial input / output: Standard: RS232 / USB. optional: Profibus, CANbus.
SPC:SPC - maximum, minimum, median, Cp, CpK.
FFT:FFT - the frequency and amplitude of a regular change in diameter.
SSFD: single scan defect detection - detection of concave and convex defects.
Helix model (HELIX): measuring the hanging or sealing diameter of the twisted product.
Presupposition: diameter, upper limit of tolerance, upper limit of tolerance, upper limit of defect, and lower limit of defect.
Glass mode: measuring transparent products.
PSU-RS2-AR: power supply unit +RS232+ analog + electric appliance.
Serial input / output: RS232 / USB, CANbus.
Speed input: this item is required when the control output or the caliper is used in the spiral mode.
Electric appliance output: 4 x relay node, rated voltage 50Vdc (1. state 2. upper limit 3. lower limit 4. SFFD).
Analog output at 1:16 10 Vdc 2mA - selectable Ø X or average.
The analog output is 10 Vdc 2mA - Ø, Y or + 10 Vdc mean error.